Jaken Medical, Inc. :: Reconditioned & Demo Cardiology Equipment :: Stress Test Systems :: Reconditioned Quinton Q4000 Stress Test System

Reconditioned Quinton Q4000 Stress Test System

Reconditioned Quinton Q4000 Stress Test System
Reconditioned Quinton Q4000 Stress Test System

DESCRIPTION:

  • Sharp CRT display – 3 channel
  • users selected leads
  • 12 Lead average
  • Simultaneous 12 Lead, Comprehensive Final Reports
  • Tabular report by stage or time, Average Beat Summary,
  • Abbreviated Trend Graph, Trend Graphs (ST level & ST Slope on all 12 leads for entire test)
  • Includes Resting Averages
  • Programmable protocols (with up to 31 stages)

ALL ACCESSORIES ARE INCLUDED

SPECIFICATIONS:

Chart Recorder
  • Records three 50 mm-wide ECG channels and a 45 mm-wide half channel containing alphanumeric data for labeling and calculated parameters
  • Writing Method: High-resolution thermal printhead. 
  • Speeds: 2, 25, and 50 mm/sec. 
  • Paper Capacity: 200 feet (61 meter) of Z-fold paper. 
  • Paper size: 8 ˝" x 11" (216 x 280 mm). 
  • Paper Type: Thermal paper, Z-fold.
ECG Computations
  • Calculated parameters: heart rate, ST level, and ST slope. 
  • Fiducial point for ST measurement: j-junction (calculated using QRS offset and isoelectric reference point).
Timers
  • Descriptions: 14-wire, low-noise, shielded cable for developing the 12 standard leads and the XYZ Frank leads. 
  • Color coded connectors comply with the 1975 AHA recommendations.
ECG Simulator
  • Outputs are simulated ECG signals for the 14 electrode sites. 
  • The simulated heart rate is adjustable to any value between 30 and 240 bpm, with a default value of 60 bpm. 
  • PVC complexes may be selected by the operator.
Rear Panels Outputs
  • QRS SYNC: TTL compatible QRS synchronization pulse ( mini-phone jack). 
  • The leading edge of the sync pulse is delayed 25 msec (nominal) form the ECG complex. 
  • Analog Output Three-channel ECG or heart rate/treadmill speed (mph)/treadmill grade (%) (3 mini-phone jacks). 
  • ECG signals are bipolar, ±5 volts, and the output signals have a gain of 1000 over the input signal. 
  • Signals are linear from 0 to +5 volts maximum. 
  • If the output is set to heart rate/speed/grade: 120 bpm= 1.0 volt; 5.0 mph = 1.0 volt; 10% grade = 1.0 volt.