Jaken Medical, Inc. :: Reconditioned & Demo Cardiology Equipment :: Stress Test Systems :: Reconditioned GE CASE 16 Stress Test System

Reconditioned GE CASE 16 Stress Test System

Reconditioned GE CASE 16 Stress Test System
Reconditioned GE / Marquette MAX 1 Stress Test System

Features:
  • Interpretive Stress Test with Marquette T2000 Treadmill
  • Patient cables digitizes the signal at the patient, eliminating analog cable noise
  • Contacts resist corrosion and ensure optimal signal quality
  • Median update helps assure all measurements, including ST segments, are are made upon true morphology
  • Technician friendly interface. Select standard or customized protocols
Technical Specifications:

  • Display : Type: high-resolution, raster written
  • Frequency response: 0.01 to 40 Hz, 0.01 to 20 Hz, user-selectable.
  • Number of traces: 3 rhythm leads. Sweep speed: 25 mm/s
  • Sweep speed accuracy: + 2%.
  • %. ECG rhythm: 7.5 s/lead.
  • Leads: user-selectable.
  • Recall reports: 10 s of 6 user-selectable leads.
  • Displayed data: heart rate, target heart rate, blood pressure, total exercise time clock, stage clock, 4 current median complexes, treadmill speed and grade, ventricular ectopic/minute counter, 3 channels of rhythm, protocol and stage of exercise, warning messages and prompts.
  • Acquisition Module: Analog Sampling rate: 2000 Hz.
  • Microprocessor-controlled: 10 IEC and AHA color-coded lead wires standard, 14 lead wires optional; (additional lead wires user-definable),
  • Keypads: Control Panel: contains manual treadmill test, test/procedures, and controls.
  • Alphanumeric keyboard: with TRIM KNOB for blood pressure, patient demographics, and impressions entry.
  • Reports: Classical 12-lead: note: reports can be transferred to the NUSE network by diskette.
  • Incrementally averaged medians: with real-time rhythm and ST level: user-selectable in two formats.
  • 3- or 6- channel rhythm strips: available for real-time, recall or arrhythmia documentation (leads user-selectable).
  • Tabular presentation of final report data including: phase, stage, speed, grade, heart rate, blood pressure, rate-pressure product, ectopic, maximum ST, depression, and physician´s impressions.
  • Sample cardiac cycles: presented at user-defined intervals.
  • Trend graph: heart rate, ST levels, ST slopes, blood pressure, PVSs/m.
  • Power Requirements: 90 to 135 VAC, 180 to 270 VAC, 50/60HZ.
  • Power consumption: 225 W. maximum.
  • Height: 154.94 cm (61 in).
  • Width: 62.23 cm (24.5 in).
  • Depth: 71.12 cm (28 in).
  • Weight: 4.48 kg (120 lbs)
Details