Jaken Medical, Inc. :: Cardiology Equipment :: Stress Test Systems :: GE Medical Systems :: GE CASE PREMIUM Stress Test System

GE CASE PREMIUM Stress Test System

GE CASE PREMIUM Stress Test System

This is a Reconditioned GE CASE PREMIUM Stress System plus T2000 Treadmill:

Features:

  • ARRY (Arrhythmia Detection/Documentation Package): Software to detect (save and/or store in test arrhythmias, serious arrhythmias are displayed in colors.
  • 2DWF (2D Waterfall Display): Display of “stacked” Median wave form with color coded amplitude.
  • BRWS (MUSE Browser): Application to allow the retrieval of any final report type data from any patient stored on the MUSE as a PDF report (ECG, Hi-Res, Stress, Holter….) Requires Network Communication option may be used outside of the exercise test application)
  • EXPD (Export Data): Export to a file (as XML or ASCII) of Final Report.
  • EPDF/EWRD (Export Report as PDF or WORD): Export to a file (as PDF or WORD) of Final report PDF supports wave forms stored in the CASE final Report Word supports only Textual and Tabular data (no wave forms) (Export of PDF file to internal Hard Drive, floppy Drive, CD-R drive).
  • DSPC (Screen display Configuration): Allows for configuration of in-test data (HR, speed, Grade, BP, RPP, METS…) change size and look of the in-test numerical data that is displayed on Right hand side of exercise test screen.
  • ITBL (In-Test Tabular Summary): Tab at top of screen allows for display of tabular summary data during exercise test (Phase, Stage, Time, Speed, Grade, Workload (METS), HR, BP, RPP, VE, #ectopic beats, Comments).
  • ITRD (In-Test Trends): Tab at top of screen allow for trend type display of Exercise data [VE/min, HR, BP, ST, ST/HR loops…]
  • PRVT (Previous Test Retrieval): Allow for previous test data to be displayed during exercise test on the current patient only (from CASE disk only as CASE format (no other option required) and / or from MUSE network as PDF format (requires Store to MUSE Network option & Network Communication option & Network Communication option if retrieval from MUSE is desire).
  • IMPD (Electrode Impedance Measurement): Graphically shows electrode location and quality of electrode as Green (good), Yellow (poor), Red (bad/fail).
  • CD-RW (Archive to CD-R Media): Allows for Archive of Exercise data from CASE hard drive database to CD-R Media.
  • RISK (Risk Factors and Scores): Provides tab for AHA CHD & Stroke risk scores as well as Duke Treadmill risk score.
  • NETS (Network Communication): Cable / Software for connection to Electronic Medical Records System.
  • RESI (12SL): GE/Marquette 12SL Resting ECG Interpretive Software. Allows for Pretest and Recovery Phase Interpreted 12 Lead ECG (limit of 5 per exercise test). 12 lead & Interpretation is displayed on Tab at top of exercise test screen.
  • EGMO: Storage of Full Disclosure ECG. Allows for review of all exercise recorded data with capability to Re-Analyze ECG data measurement point.
ALL ACCESSORIES + T2000 Treadmill ARE INCLUDED!

 

Details
SKU CSPREM
 
Price: Call for the best price on this item.
Options
Quantity

Detailed images

Send to friend

: *
: *
: *